RF Coaxial Cable List

Convert Millimeters to Inches

Common RF coaxial cable list

Cable Part No. Cable type Character Impedance

Diameter size 0 (mm)

Center Conductor Outer diameter of insulator Outer diameter of shield Outer diameter of jacket
composing outer diameter
2 SYV-50-1

SFF-50-1

50 7x0.09 0.27 0.87+0.05 1.455 1.9+0.1
RG-178/U 50 7x0.1 0.30 0.91 1.375 2.01+0.1
RG-196/U 50 7x0.1 0.30 0.86 1.375 2.03
SFF-75-1 75 Single Core 0.17 0.87 1.375 1.80
3 SYV-50-2-1 50 7x0.16 0.48 1.5+0.1 2.15 2.9+0.1
SFF-50-1.5-1 50 7x0.18 0.54 1.5+0.1 2.15 2.55+0.15
RG-174/U 50 7x0.16 0.48 1.52 2.245 2.54
RG-316/U 50 7x0.17 0.51 1.52 2.065 2.59
RG-188/U 50 7x0.18 0.54 1.52 2.065 2.79
SFF-75-1.5-1 75 7x0.1 0.30 1.50 --- 2.55
SFF-75-1.5-2 75 7x0.1 0.30 1.50 --- 3.2
SYV-75-2 75 7x0.8 0.24 1.50 2.15 2.9+0.1
RG-179B/U 75 7x0.1 0.30 1.60 2.13s 2.54
3A
RG-316DT 50 7x017 0.51 1.60 2.22d 2.80
4 SFF-50-2-1 50 Single Core 0.73 2.2 -S 3.3+0.2
SFF-75-2 75 Single Core 0.41 2.2 --- 3.2
4A SYV-50-2-2 50 7x2.3 0.68 2.2 3.1D 4.0
SFF-50-2-2 50 Single Core 0.73 2.2 -D 4.0
5 SFF-50-3-1 50 Single Core 0.93 3.0 -S 4.5+0.25
SYV-50-3 50 Single Core 0.90 3.0 3.855 5.0+0.25
RG141A/U 50 Single Core 0.99 2.95 3.715 4.83
RG58C/U 50 Single Core 0.90 2.95 3.81S 4.95
RG303/U 50 Single Core 0.99 2.95 3.71S 4.32
RG-58/U 53.5 Single Core 0.81 2.95 3.60S 4.95
SYV-75-3 75 7x0.17 0.51 2.95 3.85S 5.0+0.25
SFF-75-3-1 75 Single Core 0.55 3.0 -S 4.5
5A SFF-75-3-2 75 Single Core 0.55 3.0 -D 5.5
SFF-50-3-2 50 Single Core 0.93 3.0 -D 5.5D
RG-55/U 53.5 Single Core 0.81 2.95 4.20D 5.23
RG-142B/U 50 Single Core 0.99 2.95 4.34D 4.95
RG-223/U 50 Single Core 0.89 2.95 4.47D 5.49
RG-400/U 50 19x0.18 0.99 2.95 4.34D 4.95
6 RG-59B/U 75 Single Core 0.58 3.71 4.855 6.15
RG-140/U 75 Single Core 0.64 3.71 4.47S 5.92
SYV-50-5-2 50 Single Core 1.37 4.6+0.20 6.20D 7.8+0.30
RG-5A/U 50 Single Core 1.29 4.60 6.30D 8.33
RG-212/U 50 Single Core 1.44 4.70 6.30D 8.43
RG222/U 50 Single Core 1.41 4.70 6.30D 8.43
RG-21/U 53 Single Core 1.29 4.70 6.30D 8.43
RG-6A/U 75 Single Core 0.72 4.70 6.30D 8.43
7 SYV-50-7-1 50 7x0.75 2.26 7.3+0.25 8.55 10.2+0.30
RG0-165/U 50 7x0.80 2.40 7.25 8.64S 10.40
RG213/U 50 7x0.75 2.26 7.25 8.64S 10.29
RG215/U 50 7X0.75 2.26 7.25 8.64S 12.07*
RG-8/U 52 7x0.72 2.17 7.24 8.20S 10.29
RG-10/U 52 7x0.72 2.17 7.24 8.20S 12.07*
SYV-75-7 75 7x0.4 1.20 7.25+0.25 8.50S 10.2+0.30
RG-11/U 75 7x0.4 1.20 7.24 8.20S 10.29
RG144/U 75 7x0.45 1.35 7.25 8.38S 10.40
RG-214/U 50 7x0.75 2.26 7.25 9.14D 10.80
RG-225/U 50 7x0.79 2.38 7.24 9.14D 10.92
RG-9/U 51 7x0.72 2.17 7.11 8.70D 10.67
8 SYV-50-7-2 50 7x0.75 2.26 7.3+0.25 9.30D 11.2+0.30
9 SYV-50-9 50 --- 2.85 9.0+0.30 10.2 12.4+0.40
RG-119/U 50 --- 2.59 8.43 10.52D 11.81
10 SYV-50-12 50 --- 3.6 11.5+0.4 12.8 12+0.50
RG-34/U 71 7x0.72 2.17 11.56 12.9 15.88
RG-217/U 50   2.69 9.40 11.76D 15.62
11 SYV-50-15 50   4.62 15+0.50 16.4 19+0.50
12 SYV-75-3 75   0.51 3+0.15 3.85S 5+0.25
13 SYV-75-5-1/2 75   0.72, 0.78 4.60+0.20 5.5S 7.1+0.30
15 SYV-75-7 75 7x0.40 1.20 7.3+0.25 8.50S 10.2+0.30
16 SYV-75-9 75   1.37 9+0.30 10.2 12.4+0.40
17 SYV-75-15 75   2.46 15+0.50 16.4 19+0.50
18 SYV-75-17 75   2.85 17.3+0.70 19.3 22.2+0.60
19 SYV-100-7     0.6 7.3+0.25 8.5 10.2+0.30
20 SIV-7 SDY-7     0.3 6.6+0.20   9.6
21 SDY-4     0.64 3.7+0.25   6.2+0.40
22 SXM-50-7 50   1.68 7.3+0.30   9.9+0.60
23 SXH-50-9 50   1.4 8.7+0.40   14.5+0.90
24 SXH-75-5 75   0.78 5.4+0.30   9.2+0.60
25 SXM-75-5 75   0.68 5.5+0.30   8+0.50
26 SX-75-6 75   0.78 6+0.30   6.8+0.40
27 SYV-50-5-1 50   1.37 4.6+0.20 5.5S 7+0.30
28 SYV-50-5-2 50   1.37 4.6+0.20 6.2D 7.8+0.30
29 SYV-50-17 50   5.2 17.3+0.70 19.3 22.2+0.60
30 SYV-50-5-23-1/2 50   6.85 23+0.10 25.4+0.10 28.8+0.70
31 SYV-50-5-28-1/2     8.25 28+0.10 30+0.10 34.5+0.8
32 SYV-75-2 75 7x0.08 0.24 1.5+0.10 2.15+0.10 2.9+0.1
33 SYV-75-12 75   1.92 11.5+0.40 12.8 15+0.5
34 SYV-75-23-1/2 75   3.18 23+1.0 25+0.10 28.8+0.70
35 SYV-75-28-1/2 75   4.5 28+1.0 30+0.10 34.5+0.80

Note: 1.  Outer diameter of shield of word means:   S: single comb shield

                                                                               D: double comb shield

 
                     2.  * cable: RG-XXX/U is the model of abroad

           3.  Executive standard of domestic flexible/semi-rigid cable

                     4.  Executive standard of foreign flexible/semi-comfortable cable

 

Flexible cable semi-rigid/comfortable cable

Cable Part No.

Cable type

Character Impedance

Diameter size 0 (mm)

Center Conductor Outer diameter of insulator Outer diameter of shield Outer diameter of jacket
 Composing Outer diameter
B2 SFT-50-2-1 50 Single Core 0.51 1.67 2.2  
SFT-75-2 75 Single Core 0.27 1.67 2.2  
RG-405/U 50 Single Core 0.51 1.67 2.2  
B3 SFT-50-3-1 50 Single Core 0.93 3.0 3.6  
SFT-75-3 75 Single Core 0.55 3.0 3.6  
RG-402/U 50 Single Core 0.92 3.0 3.6  
B5 SFT-50-5.2 50 Single Core 1.60 5.20 6.0  
SFT-75--5.3 75 Single Core 0.95 5.3 6.0  

Note: 1.  Outer diameter of shield of word means:   S: single comb shield

                                                                               D: double comb shield

 
                     2.  * cable: RG-XXX/U is the model of abroad

           3.  Executive standard of domestic flexible/semi-rigid cable

                     4.  Executive standard of foreign flexible/semi-comfortable cable

 

Common corrugated copper pipe cable list

Cable Part No. Size in Inch Cable type Characeristic Impedance

Diameter size 0 (mm)

Center Conductor Insulation Outer conductor Outer diameter of jacket
composing Outer diameter composing outer diameter composing outer diameter
501 1/4"

RFF 1/4"-50(NK)

(super flexible)

50 copper line 1.9 foam polythene 4.8 helix corrugated copper pipe 6.4 7.4
FSJ1-50A (HELIAX ANDERW)

(super flexible)

50 copper line 1.9 foam polythene 4.7 helix corrugated copper pipe 6.4 7.4
502 1/4" HS1RP-50A (HELIAX ANDERW) 50 copper line --- air dielectric 4.7 helix corrugated copper pipe 6.4 7.4
504 1.4" LDF1-50(HELIAX ANDERW) 50 copper line 2.6 foam polythene   corrugated copper tube cable 7.7 8.8
511 3/8" SYFY-50-7-51 50 copper line 3.1 foam polythene --- helix corrugated copper pipe 9.7 11
512 3/8" HST2-50(HELIAX ANDERW) 50 copper line --- air dielectric --- helix corrugated copper pipe 9.5 10.5
513 3/8" RFF 3/8"--50(NK)(HELIAX ANDERW) 50 copper line 2.6 foam polythene 6.5 helix corrugated copper pipe 9.0 10.1
FSJ2-50(HELIAX ANDERW) 50 --- 2.8 air dielectric --- helix corrugated copper pipe 9.5 10.5
532 1/2" HLT4-50T(HELIAX ANDERW) 50 --- 4.8 air dielectric --- helix corrugated copper pipe 14 15.5
533 1/2" RFF 1/2"--50(NK)

(super flexible)

50   3.55 foam polythene 9.0 helix corrugated copper pipe 11.9 13.5
FSJ4-50(HELIAX ANDERW)

(super flexible)

50 --- 3.6 foam polythene --- helix corrugated copper pipe 12.2 13.5
534 1/2" LDF4-50A(HELIAX ANDERW) 50 --- 4.6 foam polythene --- corrugated copper tube cable 14 16
542 5/8" HJ4.5-50(HELIAX ANDERW) 50 --- 6.9 air dielectric --- helix corrugated copper pipe 24.9 27.5
551 7/8" VXL5-50(HELIAX ANDERW) 50 helix copper pipe 9.42 foam polythene --- helix corrugated copper pipe 24.9 27.5
552 7/8" HJ5-50(HELIAX ANDERW) 50 copper pipe 9.1 air dielectric --- helix corrugated copper pipe 25.7 28.2
553 7/8" RFF 7/8" -- 50(NK) (super flexible) 50 copper pipe 9.1 foam polythene 23.2 helix corrugated copper pipe 23.5 28.7

 

Special RF Coaxial Cable List

Cable Part No. Size in Inch Cable Type Center conductor outer diameter diameter size 0 (mm)
outer diameter of insulator outer diameter of shield outer diameter of jacket
500 1/2"SFX500PE 50 3.5 --- 10.2 11.5
540 1/2"FXL540PE 50 5 --- 13.6 15.4
601 LMR400 50 2.74 7.24 8.13 10.29
602 RG6-5 75 0.9 4.9 5.9 7.3
603 RG-11 75 2.17 7 8.7 10.67
604 LL-335 50 2.5 --- 7.1 8.4
605 TEFLX-RG401 50 1.6 5 6.5 7
606 --- 50 --- --- --- ---
607 LWR 240 50 --- --- --- ---
608 SUJ-50-7-5 50 2.6 7.2 7.7 10.5
609 --- 50 3.0 8.9 9.4 12.1
610 --- 50 1.8 4.6 5.6 7.8
612 --- 50 3 6.5 7.5 10
613 --- 50 1.3 3.3 4.4 5
614 --- 50 3.2 9 9.5 12.2
615 Astrolab 32055 50 1.5 --- --- 5.5
LI235 50 1.45 4.06 4.85 5.97
616 --- 75 0.81 5.15 --- 7.9
617 MICOV COAX(OUFB205A) 50 1.45 3.9 4.5 5.15
618 MICOV COAX(OUFB311A) 50 2.24 6.3 7.25 7.85
619 RG 223/V 50 0.89 2.95 4.47 5.49
620 E3T3 1809A --- --- --- --- ---

 

621 --- 50 1.5 4 5 6
622 --- 50 1.3 3.5 4.5 5.2
623 --- 50 2.26 5.9 6.5 7.4
624 --- 50 1.6 3.8 4.8 5.5
625 LMR-600 50 4.47 11.56 12.45 14.99
626 RG-6 75 1 4.6 5.4 6.9
627 --- 75 1.7 7.112 8.66 10.287
628 --- 50 0.95 2.8 3.4 3.9
629 VOLEX 50 1.42 3.81 4.52 6.1
630 7116-50-01 (SUHNER CABLE) 50 1.4 3.78 4.7 5.7
631 7D-FB 50 2.6 7.3 8.2 9.8
632 10D-FB 50 3.5 10 11 13
633 AFPF 100 --- --- --- ---
634 5D-FB 50 1.8 5 5.9 7.5
635 8D-FB 50 2.8 7.8 8.8 10.4
636 12D-FB 50 4.4 12.4 13.3 15.6
637 SFB-50-7 50 2.5 7.3 8.1 9.2
638 --- 100 1.3 2.7 3.3 04.2
639 Semflex LA290 50 --- --- --- ---
640 Times SFT20F 50 1.26 3.8 4.67 5.12
642 --- 50 1.6 5.1 5.8 7.2
643 LMR-195 50 0.94 2.79 3.53 4.95
644 LMR-200-50 50 1.12 2.95 3.66 4.95
645 LMR-200-75 75 0.7 2.95 3.66 4.95
646 LMR-240-75 75 0.9 4 4.52 6.1
647 LMR-400-75 75 1.6 7.4 8.13 10.3
648 LMR-600-75 75 2.1 11.56 12.45 14.99

 


2004, Sources East, all rights reserved

submit errors to sesales@sourceseast.com